Chapter 1 Description ........................... 5
Chapter 2 Installation ......................... 17
Chapter 3 Start-Up ............................. 30
Chapter 4 Troubleshooting ................. 31
Chapter 5 Maintenance ....................... 34
Chapter 6 Warranty ............................ 35
Parts List & Exploded Views ................... 36
Appendix A Installation Instructions for
Field Installed Electric Heat
ComPac
®
I and ComPac
®
II
Air Conditioner Product Manual
Vertical Wall-Mount Air Conditioners
with Front Control Box Panel
P/01655 09/2013 rev.10
Models AVPA 12-24-30-36-42-48-60-72
Models HVEA 24-30-36-42-49-60 and HVESA36-42-49-60
Manufactured By:
Marvair
®
Division of AIRXCEL
®
, Inc.
P.O. Box 400 • Cordele, Georgia 31010
156 Seedling Drive • Cordele, Georgia 31015
(229) 273-3636 • Fax (229) 273-5154
E-mail: marvairtech@airxcel.com • Internet: www.marvair.com
The most current version of this manual can be found at www.marvair.com.
Seitenansicht 0
1 2 3 4 5 6 ... 39 40

Inhaltsverzeichnis

Seite 1 - I and ComPac

Chapter 1 Description ... 5Chapter 2 Installation ... 17Chapter 3 Start-Up ...

Seite 2 - Important Safety Precautions

10ComPac 9/2013 rev. 10IMPORTANT: The electrical wire and breaker or fuses must be sized for simultaneous operation of the electric heater and the a

Seite 3 - Table of Contents

11ComPac 9/2013 rev. 10Cold Climate Kit (AVPA 24-72 units)Controls and components which allow the units to operate in extremely cold temperatures. T

Seite 4 - Illustrations

12ComPac 9/2013 rev. 10Figure 1a. Typical Electrical Schematic - ComPac® I A/C, Model AVPA

Seite 5

13ComPac 9/2013 rev. 10GENERAL NOTES:1. 208/230 VOLT 60 Hz 1Ø POWER SUPPLY. SEE DATA PLATE FOR AMPACITY & FUSE SIZE. OPTIONAL CKT BKR SHOWN.2.

Seite 6 - Product Data Sheet

14ComPac 9/2013 rev. 10Figure 1c. Typical Electrical Schematic - ComPac® I A/C, Model HVEA

Seite 7

15ComPac 9/2013 rev. 10GENERAL NOTES:1. 208/230 VOLT 60 Hz 1Ø POWER SUPPLY. SEE DATA PLATE FOR AMPACITY & FUSE SIZE. OPTIONAL CKT BKR SHOWN.2.

Seite 8

16ComPac 9/2013 rev. 101.9 Economizer Components (ComPac® II A/C Only)Damper Actuator:The damper actuator is a 24V motor that modulates the positio

Seite 9 - Not available on the AVPA12

17ComPac 9/2013 rev. 10Chapter 2 Installation WARNINGFailure to observe and follow Warnings and Cautions and these Instructions could result in dea

Seite 10

18ComPac 9/2013 rev. 10standards. Marvair® strongly recommends referring to the current edition of the National Fire Protection Associat

Seite 11

19ComPac 9/2013 rev. 10P/N DescriptionS/04581 CommStat 3 Controller, Solid State Lead/Lag ControllerS/07846 CommStat 4 Controlle

Seite 12 - ComPac 9/2013 rev. 10

2ComPac 9/2013 rev. 10How To Use This Manual This manual is intended to be a guide to Marvair's ComPac® line of vertical air conditioners. It c

Seite 13

20ComPac 9/2013 rev. 10 WARNINGFIRE HAZARDImproper adjustment, alteration, service, maintenance or installation could cause serious injury, death an

Seite 14

21ComPac 9/2013 rev. 10BACK PANEL CONFIGURATION BACK PANEL CONFIGURATIONFOR 17" x 17" (432mm x 432) WALL SLEEVE FOR 26" x 17" (6

Seite 15

22ComPac 9/2013 rev. 10DuctingExtensions should be cut ush with the inside wall for applications without duct work.Applications using duct work sho

Seite 16

23ComPac 9/2013 rev. 100%5%1 0 %1 5 %0%5%10%15%0%5%1 0 %1 5 %Figure 4a. Fresh Air Hood Damper,Models 24-72Figure 4b. Fresh Air Hood Damperfor AVPA1

Seite 17 - Chapter 2 Installation

24ComPac 9/2013 rev. 10For units with electric heat, a one inch clearance is required around the duct extensions. The duct extensions must be constr

Seite 18 - Table 5. Voltage Limitations

25ComPac 9/2013 rev. 102.8 Electrical Connections WARNING ELECTRICAL SHOCK HAZARDFailure to follow safety warnings exactly could result in serious

Seite 19

26ComPac 9/2013 rev. 102. Connect the wires to the input side of the internal breaker or terminal block (L1 & L2 for single-phase units; L1, L2

Seite 20 - FIRE HAZARD

27ComPac 9/2013 rev. 10Continuous fan operation: For continuous indoor fan operation on single units, install a jumper between terminals 8 and 3.

Seite 21

28ComPac 9/2013 rev. 10CommStat 4 Lead /Lag ControllerPlease refer to the Product Data sheet for the Commstat 4 controller for complete instructions

Seite 22

29ComPac 9/2013 rev. 10Figure 6c. LL357D4 Wiring Diagram & Thermostat KeysLORGWCYRCommStat 3Low Building Temp AlarmSmoke Alarm+24v.+48v24/48 co

Seite 23 - Models 24-72

3ComPac 9/2013 rev. 10 WARNING• If the information in these instructions are not followed exactly, a re may result causing property damage, persona

Seite 24

30ComPac 9/2013 rev. 10Chapter 3 Start-Up3.1 Check-Out of Cooling CycleImportant: Be sure that the crankcase heater (if used) has been energized

Seite 25 - ELECTRICAL SHOCK HAZARD

31ComPac 9/2013 rev. 10Chapter 4 Troubleshooting4.1 OverviewA comprehensive understanding of the operation of the ComPac® A/C is a prerequisite to

Seite 26

32ComPac 9/2013 rev. 10PROBLEM/SYMPTOM LIKELY CAUSE(S) CORRECTIONC. Unit cycles on high/low pressure limit.1. Loss or restriction of airow

Seite 27

33ComPac 9/2013 rev. 103. Motor Winding Resistances: Using a digital volt-ohm meter (VOM), measure the resistance across the compressor windi

Seite 28

34ComPac 9/2013 rev. 10Chapter 5 Maintenance5.1 Scheduled MaintenanceMarvair® strongly recommends that the air conditioner be serviced a minimum o

Seite 29

35ComPac 9/2013 rev. 10Chapter 6 Warranty6.1 Limited Product WarrantyIf any part of your Marvair® Air Conditioner, Heat Pump or Unit Ventilator fa

Seite 30 - Chapter 3 Start-Up

36ComPac 9/2013 rev. 10EXPLODED VIEWS AND PARTS LISTS Current parts lists and exploded views of the unit can be found on our web site at www.marv

Seite 31 - Chapter 4 Troubleshooting

37ComPac 9/2013 rev. 10galvanized steel with a minimum thickness of .019 inches for the rst 3 feet (1 meter). Ductwork must be rmly attached, secu

Seite 32

38ComPac 9/2013 rev. 10

Seite 33

39ComPac 9/2013 rev. 10NOTES

Seite 34 - Chapter 5 Maintenance

4ComPac 9/2013 rev. 10Table of ContentsChapter 5 Maintenance5.1 Scheduled Maintenance ...

Seite 35 - Chapter 6 Warranty

40ComPac 9/2013 rev. 10NOTES

Seite 36

5ComPac 9/2013 rev. 10Chapter 1 Description & Specications1.1 General DescriptionMarvair's ComPac® lines are a series of vertical wall-mo

Seite 37

6ComPac 9/2013 rev. 101.4 Air Flow, Weights and Filter SizesComplete electrical and performance specications and dimensional drawings are

Seite 38

7ComPac 9/2013 rev. 101.5 General OperationRefrigerant Cycle (Cooling Mode)The ComPac® I & ComPac® II A/C use R-410A refrigerant in a convention

Seite 39

8ComPac 9/2013 rev. 10Delay on BreakIf the compressor is de-energized due to a loss of a cooling “Y” call or the rst fault, the unit re-start will b

Seite 40

9ComPac 9/2013 rev. 10LEDsPOST PURGE WHEELDELAY ON MAKE(COMPRESSOR TIME DELAY)WHEEL1.7 Optional Controls & PackagesHard Start KitUsed on single p